SPP-BOILER drum unit · mechanics & protection

JV_PSPP_TEST / SPP-BOILERHARAIEC 61508 · SIL 2
t 0.00 s

Unit mimic

Running
Fuel FURNACE tube metal 340 °C DRUM LC ref. leg Stop valve100 % Governor100 % HP TURBINE GENERATOR Breakerclosed Condenser Feed pumprunning Feed valveauto feedwater 100 kg/s steam 100 kg/s

Trends

limittrip set point

Safety goals

this run
GoalLimitRun extreme

Sequence of events

Model parameters (SPP-ASM-01) and simulation assumptions

Sim-only assumptions, not in WCGW: a boiler trip also trips the turbine; a reverse-power relay opens the breaker 1 s after steam is lost; level control is three-element and uses the DP median; drained reference leg biases DP channels +450 mm; conductivity electrodes every 50 mm; 2.5 kg/s fuel per burner, unburnt fuel swept out with τ = 3 s, explosive accumulation limit 25 kg; tube metal creep limit 480 °C; feed pump runout 160 kg/s.

Lumped-parameter sketch built from work item SPP-BOILER in WCGW. Illustrative numbers only, not real project data, and not a substitute for a validated plant model.